This easy to install and set-up, all-in-one system also offers PA broadcasting, paging and BGM functions that operate with uncompromisingly high audio quality to ensure consistently high intelligibility. The VM-3000 Series is digitally audio processed and controlled, with full digital audio mixing and a built-in high-quality electronic voice message feature. The system may be set up directly using the controls and LCD display on the front panel, also enabling easy operation of the system. Operational versatility is further enhanced by a dedicated software configuration capability for entering and updating settings via a PC. Each extension amplifier offers a local paging/BGM input.
Specifications
-
Power Source:AC mains, 50/60 Hz DC: 24 V DC
-
Power Consumption:850W
-
Rated Output:360W
-
Frequency Response:50 – 20,000 Hz, ±3dB (at 1/3 rated output)
-
Distortion:Under 0.8% (at rated output, 1kHz)
-
Signal-to-Noise Ratio:Over 85dB
-
Input:External Amp Input : 100V LINE Plug-in screw connector
-
Audio Input:-50 dB (MIC)/-10 dB (LINE) (changeable) 600Ω, electronically balanced plug in screw connector
-
Output:
-
Speaker output 1 – 2 : max (360w) per output
-
Speaker output 3 - 6 : max (120w) per output
-
Total with in 360W
-
Plug-in screw connector
-
Direct output : Direct output from internal or external amplifier
-
Plug-in screw connector
-
RM Link 1.2 in:–
-
Network I/F:–
-
VM Link:
-
RJ45 female connector
-
VM LINK IN : for connecting the VM-3240VA or VM-3360VA
-
VM LINK OUT : for connecting the VM-3240E or VM-3360E
-
Maximum distance : 800 m
-
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
-
EXT PA Link:
-
RJ45 female connector for connecting the VP-2241 or VP-2421
-
Maximum distance : 5 m
-
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
-
General Control In: 1 – 8/Out: 1 – 8:
-
Plug-in screw connector
-
Input : No-Voltage make contact input, open voltage: 24V DC, short-circuit current: under 1 mA
-
Output : Isolated open collector output, withstand voltage: 30V DC, operating current: under 50 mA
-
Emergency Control In: 1 – 6/Status out:
-
RJ45 female connector
-
Input 1 – 5 : No-Voltage make contact input, open voltage : 24V DC, short-circuit current: under 2 mA
-
Connection resistance to make the function: Inactive; 9.4kΩ ±5%/Active; 4.7kΩ ±5%
-
Input 6: Isolated voltage input: Inactive; -24V ±20%/Active; +24V ±20%
-
Status out: Relay contact output, withstand voltage: 40V DC, operating current: 2 – 300mA
-
ATT Control:Plug In connector, relay contact, 30V DC, 125V AC 5A (AC/DC)
-
Power In/Out PS Out/DC Power In:
-
M4 Screw terminal distance between barriers 11 mm
-
This connector for connecting the VX-2000DS only
-
DC 28V/30A (operating range: 20 - 40V DC)
-
DC24V Output:24V DC ±10% Maximum feeding current 0.4A
-
DS Link:
-
RJ45 female connector for connecting the VX-2000DS
-
Maximum distance: 5 m
-
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
-
Dimensions:482 (W) x 132.6 (H) x 460 (D)mm
-
Weight:19kg
-
Option:Input transformer: IT-450